一(yi)、WBDG-2000全自(zi)動三相電(dian)容電(dian)感測試(shi)儀產品概述
無(wu)功(gong)補(bu)(bu)償(chang)電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)器(qi)(qi)(qi)(qi)(qi)是(shi)滿(man)足電(dian)(dian)(dian)(dian)(dian)力系(xi)統無(wu)功(gong)平(ping)衡(heng)的(de)(de)重(zhong)要設(she)備。近年來無(wu)功(gong)問題(ti)得到(dao)了電(dian)(dian)(dian)(dian)(dian)業部(bu)門的(de)(de)普(pu)遍重(zhong)視(shi),無(wu)功(gong)補(bu)(bu)償(chang)成套(tao)裝置(zhi)已(yi)大量(liang)投(tou)入配(pei)電(dian)(dian)(dian)(dian)(dian)網(wang)運(yun)行。電(dian)(dian)(dian)(dian)(dian)能(neng)(neng)供給要求系(xi)統有(you)(you)功(gong)與(yu)無(wu)功(gong)實時平(ping)衡(heng)。因此,無(wu)功(gong)補(bu)(bu)償(chang)裝置(zhi)應滿(man)足自動(dong)跟蹤、實時補(bu)(bu)償(chang)的(de)(de)要求,這(zhe)就(jiu)(jiu)不可避免(mian)地要頻繁(fan)投(tou)、切無(wu)功(gong)補(bu)(bu)償(chang)電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)器(qi)(qi)(qi)(qi)(qi)組(zu)(zu)。電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)器(qi)(qi)(qi)(qi)(qi)組(zu)(zu)的(de)(de)投(tou)、切操(cao)作,就(jiu)(jiu)會產生過電(dian)(dian)(dian)(dian)(dian)流與(yu)過電(dian)(dian)(dian)(dian)(dian)壓沖擊,引起電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)器(qi)(qi)(qi)(qi)(qi)損壞(huai)。為保證(zheng)設(she)備的(de)(de)可靠性(xing),早(zao)期(qi)發現電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)器(qi)(qi)(qi)(qi)(qi)缺陷(xian),避免(mian)故障擴大,需(xu)要定期(qi)進行檢(jian)測(ce)。而在現場電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)器(qi)(qi)(qi)(qi)(qi)都是(shi)成組(zu)(zu)并(bing)聯的(de)(de),傳統方(fang)法是(shi)將電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)匯流排拆(chai)除,然(ran)后用老式電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)表進行測(ce)量(liang),由于電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)器(qi)(qi)(qi)(qi)(qi)組(zu)(zu)是(shi)由幾十至上百個小電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)器(qi)(qi)(qi)(qi)(qi)組(zu)(zu)成,要拆(chai)線(xian)(xian)(xian)測(ce)量(liang)電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)量(liang)的(de)(de)工(gong)作量(liang)很大,而且經常(chang)拆(chai)線(xian)(xian)(xian)會使得螺(luo)絲滑牙或沒有(you)(you)上緊(jin)而留下**隱(yin)患,也容(rong)(rong)(rong)(rong)(rong)易造成電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)的(de)(de)二(er)次損壞(huai)。因此,非常(chang)期(qi)望有(you)(you)一種測(ce)試儀(yi)器(qi)(qi)(qi)(qi)(qi)不用拆(chai)線(xian)(xian)(xian)就(jiu)(jiu)能(neng)(neng)測(ce)量(liang)各個小電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)器(qi)(qi)(qi)(qi)(qi)的(de)(de)電(dian)(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)(rong)量(liang),減(jian)輕檢(jian)修(xiu)人員的(de)(de)負擔,提(ti)高(gao)(gao)檢(jian)修(xiu)工(gong)作的(de)(de)效率(lv),提(ti)高(gao)(gao)配(pei)電(dian)(dian)(dian)(dian)(dian)網(wang)運(yun)行的(de)(de)**性(xing)。
針(zhen)對現場的(de)實際情況(kuang),我公司經過攻關,*終研制(zhi)出一種利用新試驗方法進行測(ce)量(liang)(liang)的(de)儀器,這就是三相電(dian)容(rong)(rong)電(dian)感(gan)測(ce)試儀。該儀器可(ke)以在不拆線的(de)狀態(tai)下,測(ce)量(liang)(liang)成組(zu)并聯電(dian)容(rong)(rong)器的(de)單相電(dian)容(rong)(rong)或各種組(zu)合連接類型(xing)的(de)三相電(dian)容(rong)(rong)器,同(tong)時也能夠測(ce)量(liang)(liang)各種電(dian)抗器的(de)電(dian)感(gan),本儀器還能測(ce)量(liang)(liang)工頻狀況(kuang)下的(de)電(dian)流(liu),該儀器接線方便,操作(zuo)簡單,減輕了檢(jian)修(xiu)人(ren)員的(de)工作(zuo)負擔,大大提(ti)高了現場的(de)測(ce)試效率,為電(dian)網(wang)的(de)正常運行提(ti)供(gong)了**保障。
二、WBDG-2000全自動三相電容(rong)電感測試儀功(gong)能特(te)點
本(ben)儀(yi)(yi)器可在不拆線情況(kuang)下(xia)測(ce)量(liang)(liang)成組(zu)并聯電(dian)(dian)容器的單個單相電(dian)(dian)容及同(tong)時(shi)測(ce)量(liang)(liang)各種連接類型的三相電(dian)(dian)容,同(tong)時(shi)本(ben)儀(yi)(yi)器也能測(ce)量(liang)(liang)各種電(dian)(dian)抗器的電(dian)(dian)感量(liang)(liang),還可以做為工頻電(dian)(dian)流測(ce)試儀(yi)(yi)使用(yong),一(yi)機(ji)三用(yong),滿足(zu)現(xian)場的多(duo)種使用(yong);
測量時本儀器顯(xian)示測量電容(rong)值(zhi)或電感(gan)值(zhi)的同時還可以(yi)顯(xian)示測量的電壓(ya)、電流、功率、頻(pin)率、阻抗(kang)、相(xiang)位角等數據,以(yi)便更好的分析(xi)試品的好壞;
儀器采用(yong)240×128大(da)屏幕帶背光的液晶顯示(shi),白(bai)天夜間均能清晰觀(guan)察,中文(wen)菜單提示(shi),操作簡便;
儀器(qi)內(nei)置大容量非易(yi)失性存儲器(qi):可存儲50組測(ce)量(liang)數據;
儀(yi)器內置(zhi)高精度實時時鐘功能(neng):可進行日期(qi)及時間校準;
儀器自帶(dai)高速微型(xing)熱敏打印機:可(ke)打印測量及歷史(shi)數據;
儀器試驗電(dian)源過(guo)流保護功(gong)能:電(dian)源輸(shu)出短路不會損壞(huai)儀器。
三、WBDG-2000全自動三(san)相(xiang)電(dian)容電(dian)感測試儀技術指標
輸(shu)出(chu)電壓(ya) ~2V, ~20V
輸出(chu)電流: ≤10A
測量范圍
電容:0.1uF~2000uF
電感:0.1mH~10H
電流(liu):1mA~10A
電壓: 0 ~25V
測量(liang)精(jing)度
電容:±(1%+2字(zi))
電感:±(1%+5字)
電流:±(1%+2字)
電壓(ya):±(1%+2字)
外(wai)形尺(chi)寸 350mm×230mm×190mm
儀器重(zhong)量 8kg
四、WBDG-2000全自動三相電容電感測(ce)試儀使用條件(jian)
環境溫度 -10℃~50℃
環境(jing)濕(shi)度(du) ≤85%RH
工作電(dian)源 AC220V±10%
電源頻(pin)率 50±1Hz
儀器功(gong)率(lv) 200W
五、WBDG-2000全自動三相電容電感測試儀(yi)面(mian)板介紹
Ua、Ub、Uc、Uo:測(ce)試線電(dian)源電(dian)壓輸出端;
ua、ub、uc、 uo :測試線采樣電壓(ya)引入端(duan);
Ia、Ib、Ic:電流鉗接(jie)線引入端(duan);
電源開關:接通(tong)和(he)斷開交流電源;
FUSE : 保(bao)險盒
:儀器接地端子
液 晶 屏:顯示(shi)操作提(ti)示(shi)及(ji)測量(liang)數(shu)據
鍵 盤(pan):儀器各(ge)種功能的(de)操作
打 印 機:打印各(ge)種測(ce)量數據(ju)
六、操作說明
當儀器按要求(qiu)接好測試(shi)線及電(dian)源(yuan)線后,打開電(dian)源(yuan)開關(guan),液晶(jing)顯示開機界面,如下圖(tu):
延時(shi)兩三秒鐘后液晶顯示(shi)主菜單,如下圖(tu)所(suo)示(shi):
如(ru)果(guo)需要電容測(ce)試(shi),在(zai)主菜(cai)單畫面下(xia),按(an)↑ ↓鍵,選(xuan)擇 電容測(ce)試(shi) 后,按(an) 確認 鍵,進入電容測(ce)量設定畫面,如(ru)下(xia)圖(tu)所示:
在(zai)電容(rong)(rong)(rong)測量界面(mian),按↑ ↓鍵(jian)選(xuan)擇(ze)被測電容(rong)(rong)(rong)類型,按 確認 鍵(jian)進(jin)入如下顯示(shi)界面(mian)(選(xuan)擇(ze)單(dan)相電容(rong)(rong)(rong)):
經過(guo)幾(ji)秒鐘(zhong)時間,顯示(shi)(shi)測(ce)試結果如(ru)下圖所示(shi)(shi):
如果要打印(yin)數(shu)據,請按打印(yin)鍵,存(cun)儲數(shu)據請按F1鍵(jian),如果還(huan)需測量(liang)同相電壓下的(de)其他(ta)單相電容(rong),可按返回(hui)鍵(jian)返回(hui)電容(rong)測試(shi)界(jie)面,將電流鉗夾到被測電容(rong)上(shang),按確認鍵(jian)重新(xin)測量(liang)。
在電(dian)(dian)容測量界面,如(ru)果(guo)要測試三(san)(san)相電(dian)(dian)容,首先(xian)根據連接(jie)類型將所需測試線連接(jie)好,請按↑ ↓鍵選(xuan)擇被測三(san)(san)相電(dian)(dian)容類型,比如(ru)如(ru)果(guo)選(xuan)擇三(san)(san)相△型電(dian)(dian)容測試,屏幕顯(xian)示的界面如(ru)下圖所示:
按 確認 鍵進入如下(xia)顯示界面(mian):
經過(guo)一段時間,顯示測(ce)試結果如下圖(tu)所示:
存儲數據請按F1鍵,打印數據請按(an)打印鍵,按(an)返回鍵返回電(dian)容(rong)測試(shi)界(jie)面,其他連接類型的三(san)相電(dian)容(rong)測試(shi)方(fang)法與上類同。按(an)返回鍵或復位(wei)鍵可回到主菜單。
電感測(ce)試(shi)(shi)及電流測(ce)試(shi)(shi)與電容測(ce)試(shi)(shi)操作類同,不再重(zhong)復介紹。
如果需要設(she)置(zhi)(zhi)(zhi)時間可按(an)← →及(ji)↑ ↓鍵,選中時間設(she)置(zhi)(zhi)(zhi),按(an)確(que)認鍵進入設(she)置(zhi)(zhi)(zhi)界面如下:
按(an)← →改變(bian)光(guang)標前后位置,按(an)↑ ↓鍵(jian)(jian)改變(bian)光(guang)標處當前值的大小(xiao),設(she)置完成(cheng)可按(an)返(fan)回(hui)鍵(jian)(jian)或(huo)復(fu)位鍵(jian)(jian)返(fan)回(hui)主菜單。
參數(shu)設置(zhi)(zhi)為出廠校準時(shi)設置(zhi)(zhi),建議(yi)客戶不得改(gai)變(bian)其(qi)設置(zhi)(zhi)數(shu)據,否則會造成測(ce)試數(shu)據的不準。如(ru)果需要重新更(geng)改(gai),必(bi)須在本公司(si)技術人員指導下(xia)進行,并(bing)且先要記錄下(xia)更(geng)改(gai)前的設定(ding)值,以便設置(zhi)(zhi)失敗時(shi)能夠恢復初始值。
如果想查(cha)(cha)詢已存儲的記(ji)錄,可在主菜(cai)單下選擇查(cha)(cha)詢記(ji)錄,按確認鍵進(jin)入顯示如下:
按↑ ↓鍵(jian)查詢所(suo)需(xu)記(ji)錄,按打(da)印(yin)鍵(jian)可打(da)印(yin)當前記(ji)錄,如果(guo)要刪(shan)除記(ji)錄,可按F2鍵進行刪除,刪除完成(cheng)后所(suo)有(you)記錄均清零。按返回鍵或復位鍵可返回主菜單。
測試數據中各符號的含義:
⑴、I:被測電容(抗)器的(de)電流有(you)效值,單位為(wei)A(安培);
⑵、U:被測電容(抗(kang))器的電壓有(you)效值,單位為V(伏特);
⑶、P:被測電容(抗)器的有(you)功功率有(you)效值,單位(wei)為W(瓦(wa));
⑷、F:輸出(chu)電(dian)源(yuan)的(de)當(dang)前(qian)頻率,單位為Hz(赫茲(zi));
⑸、Rc:被測電容器(qi)的容抗,單位為Ω(歐姆);
⑹、Rl:被測電抗器的(de)感抗,單位(wei)為Ω(歐姆);
⑺、Rz:被(bei)測試品的阻抗,單位為(wei)Ω(歐姆(mu));
⑻、C:被測試電容器的電容值,單位為uF(微法);
⑼、Cab:被(bei)測三相電容器的AB相電容值,單位為uF(微法);
⑽、Cbc:被(bei)測(ce)三(san)相電(dian)容(rong)器的BC相(xiang)電容值,單(dan)位為uF(微法);
⑾、Cca:被測三相電容器的(de)CA相電容值,單位為uF(微法);
⑿、Ca:被測三相電容器的A相電容值,單位為(wei)uF(微法);
⒀、Cb:被測三(san)相電容器的B相電容值,單(dan)位為uF(微法);
⒁、Cc:被測三相電容器的C相電容值(zhi),單(dan)位為uF(微法(fa));
⒂、Cz:被測三相電容器總(zong)的電容值,單位為uF(微法);
⒃、L:被測(ce)電抗器的當前測(ce)量電感值,單位為H(亨(heng));
⒄、Ф:被測試品(pin)的(de)電(dian)壓與電(dian)流之間的(de)相位角,單位為 o(度)
七、測試接線(xian)
單(dan)相電容的(de)測量(liang):
單(dan)相電(dian)容測(ce)試時,將紅(hong)測(ce)試線一端(duan)接(jie)在Ua、ua上,另(ling)一(yi)端測試鉗接在一(yi)條母線(xian)上,黑測試線(xian)一(yi)端接在Uo、uo上(shang),另(ling)一(yi)端接(jie)在(zai)另(ling)一(yi)條母線上(shang),鉗形(xing)CT輸出線(xian)接到(dao)儀器(qi)Ia端,鉗形CT夾(jia)在與(yu)紅(hong)測試鉗相(xiang)連(lian)母線的(de)電容引入端,連(lian)線時要(yao)注意電流鉗上標有“P”的一端朝向電(dian)容方向夾在(zai)電(dian)容器(qi)上,否則測試的相位角不正確。
如果電(dian)容器組有多個單相(xiang)電(dian)容需要(yao)測試(shi)(shi),可(ke)以在(zai)測試(shi)(shi)完**個電(dian)容值后按返回(hui)鍵,電(dian)壓測試(shi)(shi)線不(bu)用動,直(zhi)接(jie)將測試(shi)(shi)電(dian)流的電(dian)流鉗打開然(ran)后夾到下一(yi)個電(dian)容上按確(que)認鍵進行測試(shi)(shi),這樣可(ke)大大的提高測試(shi)(shi)速度,這才是本儀器的*大特(te)色。
(2)三相△型電容的測量:
圖13是(shi)三相(xiang)△形(xing)電容測量(liang)接線(xian)方法,測量(liang)線(xian)由儀(yi)器測量(liang)輸出端按顏色對(dui)應(ying)接好,將(jiang)紅(hong)色夾子夾在(zai)母線(xian)排A相上、綠色(se)夾(jia)子(zi)夾(jia)在母(mu)線B相(xiang)上(shang),紅色夾(jia)子夾(jia)在(zai)母線(xian)C上,然后將三個(ge)電流測量線分別(bie)對應(ying)插在(zai)儀器Ia、Ib、Ic上擰緊、鉗形傳(chuan)感器對應套在(zai)高壓電容器組A相、B相(xiang)、C相引(yin)入(ru)線上,要注意各鉗型電流(liu)互感器的(de)方向是否正確,否則(ze)會造成所測電容的(de)相位角錯(cuo)誤。
(3)三相(xiang)Y型電容(rong)的測量:
三相Y型電容與(yu)△形聯接(jie)電容器的(de)接(jie)線方(fang)法一樣,只是測量時選(xuan)擇三相(xiang)Y型電容測量。這(zhe)里不再做具(ju)體介紹(shao)。
(4)三相Yn型電容的測量:
圖14是三相Yn型電容測量接線方法,測量線由儀(yi)器測量輸出端按顏色對應接好,將紅色夾子夾在(zai)母線排(pai)A相上、綠(lv)色(se)夾(jia)子(zi)夾(jia)在母線B相上,紅(hong)色夾子夾在母線C上,黑(hei)色(se)夾子夾在母線(xian)N上,然后將三個電流測量線分別(bie)對應插在儀器Ia、Ib、Ic上擰緊、鉗形傳感器(qi)對應套在高壓電容器(qi)組A相、B相(xiang)、C相(xiang)引入(ru)線上,要(yao)注意各鉗型電(dian)流互感器的(de)(de)方向(xiang)是(shi)否正確,否則會造成所(suo)測(ce)電(dian)容的(de)(de)相(xiang)位角錯(cuo)誤(wu)。
(5)三(san)相III型(xing)電(dian)容(rong)的(de)測(ce)量(liang):
圖(tu)15為三相Ⅲ型電容器(qi)(qi)測量(liang)接線方法,測量(liang)線由(you)儀器(qi)(qi)測量(liang)輸出端按(an)顏色對(dui)應插好(hao),將黃(huang)色夾(jia)子夾(jia)在母(mu)線排A相上,將綠(lv)色夾子夾在母(mu)線排B相上,將紅色夾子(zi)夾在母線排C相(xiang)上,黑色(se)夾子夾在A’線上,將(jiang)A‘B’C‘短接(jie),然后(hou)將三個(ge)電流測(ce)量線分別對應插(cha)在儀(yi)器(qi)Ia、Ib、Ic上(shang)擰緊、鉗形傳感器對應套在高壓電容器組A相、B相、C相(xiang)引入線上。
(6)電(dian)抗(kang)器電(dian)感(gan)的(de)測量:
電抗(kang)器電感測試時(shi),將(jiang)紅測試線(xian)一端接在Ua、ua上,另一端測試(shi)鉗接在電(dian)抗器一引出端上,黑測試(shi)線一端接在Uo、uo上,另一端接(jie)在電(dian)抗器另一引出(chu)端上,鉗形CT輸出線接到儀器Ia端,鉗形CT夾在與紅測試鉗相連電抗器引出端(duan),連線時(shi)要注意電流鉗上標有“P”的一端朝(chao)向(xiang)(xiang)電抗器方向(xiang)(xiang)夾(jia)在(zai)電抗器上,否則(ze)測試的相位角不正確(que)。
八(ba)、產品成套(tao)性:
部 件
|
數量
|
部 件
|
數(shu)量
|
電(dian)容電(dian)感測試儀(yi)主機(ji)
|
1臺
|
鉗形電流傳感器
|
3個
|
測試線
|
1套
|
5A保險管250V
|
2個
|
儀器(qi)電源線
|
1根
|
產品出廠(chang)合格證
|
1張
|
儀器(qi)使(shi)用說明書
|
1本(ben)
|
接地線
|
1條
|
保修卡
|
1張
|
打印紙(zhi)
|
2卷
|
|
|
裝箱單(dan)
|
1張
|
用戶(hu)收到儀器(qi)后,按照(zhao)儀器(qi)的(de)成套說明,開箱檢查是否相符,核對(dui)上述內容,若發生缺少,請(qing)立即與本公(gong)司聯(lian)系。
九、注(zhu)意事(shi)項
8.1使用本(ben)儀器前請仔細(xi)閱讀使用說明書,檢查接線無(wu)誤(wu)、接地良好。
8.2高(gao)精度電流鉗為本(ben)儀器測量的關(guan)鍵(jian)部件,受損后對測試數據有很大(da)的影(ying)響(xiang),在使用過程中需(xu)謹慎,要輕拿輕放(fang),不能(neng)從高(gao)空掉落或者摔(shuai)碰。
8.3在測(ce)(ce)量(liang)完畢并退出測(ce)(ce)量(liang)狀(zhuang)態后,關閉(bi)儀器電源,方(fang)可進行接線拆除。
8 .4如出(chu)現無(wu)法解決的問題(ti),請及時(shi)與本公司取(qu)得(de)聯系。
十(shi)、售后服務(wu)
儀器自購(gou)買(mai)之(zhi)日起一年內,屬產品(pin)質量問題免費(fei)包修包換,終(zhong)身提供(gong)維修和技(ji)術服務(wu)。如(ru)發現儀器有異常情(qing)況或故(gu)障(zhang)請與公司及時聯(lian)系,以便為您安(an)排*便捷的處理(li)方案。