一、WBDG-2000三相電(dian)容(rong)電(dian)感測試儀產(chan)品概述(shu)
無(wu)功補(bu)(bu)償(chang)(chang)(chang)電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)器(qi)(qi)是滿足(zu)電(dian)(dian)(dian)(dian)力(li)系(xi)統無(wu)功平衡的(de)(de)(de)(de)重(zhong)要(yao)設(she)(she)備。近年來無(wu)功問(wen)題得到了電(dian)(dian)(dian)(dian)業部(bu)門的(de)(de)(de)(de)普(pu)遍重(zhong)視,無(wu)功補(bu)(bu)償(chang)(chang)(chang)成套(tao)裝置已大(da)量(liang)投入配電(dian)(dian)(dian)(dian)網(wang)運(yun)行。電(dian)(dian)(dian)(dian)能供給要(yao)求(qiu)系(xi)統有(you)功與無(wu)功實時平衡。因此,無(wu)功補(bu)(bu)償(chang)(chang)(chang)裝置應滿足(zu)自動跟蹤、實時補(bu)(bu)償(chang)(chang)(chang)的(de)(de)(de)(de)要(yao)求(qiu),這就不(bu)可避(bi)免(mian)地要(yao)頻繁投、切無(wu)功補(bu)(bu)償(chang)(chang)(chang)電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)器(qi)(qi)組。電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)器(qi)(qi)組的(de)(de)(de)(de)投、切操作,就會(hui)產生(sheng)過電(dian)(dian)(dian)(dian)流(liu)與過電(dian)(dian)(dian)(dian)壓沖擊(ji),引起電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)器(qi)(qi)損壞(huai)。為保證設(she)(she)備的(de)(de)(de)(de)可靠(kao)性,早期(qi)發現電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)器(qi)(qi)缺陷(xian),避(bi)免(mian)故障擴大(da),需要(yao)定期(qi)進行檢測(ce)(ce)。而(er)在現場電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)器(qi)(qi)都是成組并(bing)聯(lian)的(de)(de)(de)(de),傳(chuan)統方法是將電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)匯(hui)流(liu)排(pai)拆(chai)除,然后用(yong)(yong)老(lao)式電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)表進行測(ce)(ce)量(liang),由(you)(you)于電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)器(qi)(qi)組是由(you)(you)幾十至上百個小電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)器(qi)(qi)組成,要(yao)拆(chai)線測(ce)(ce)量(liang)電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)量(liang)的(de)(de)(de)(de)工(gong)作量(liang)很大(da),而(er)且經(jing)常(chang)拆(chai)線會(hui)使得螺絲滑牙或沒有(you)上緊而(er)留下**隱患,也(ye)容(rong)(rong)(rong)(rong)易造成電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)的(de)(de)(de)(de)二次(ci)損壞(huai)。因此,非(fei)常(chang)期(qi)望有(you)一種測(ce)(ce)試儀(yi)器(qi)(qi)不(bu)用(yong)(yong)拆(chai)線就能測(ce)(ce)量(liang)各個小電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)器(qi)(qi)的(de)(de)(de)(de)電(dian)(dian)(dian)(dian)容(rong)(rong)(rong)(rong)量(liang),減(jian)輕檢修(xiu)人員的(de)(de)(de)(de)負擔,提高檢修(xiu)工(gong)作的(de)(de)(de)(de)效率(lv),提高配電(dian)(dian)(dian)(dian)網(wang)運(yun)行的(de)(de)(de)(de)**性。
針對現(xian)場的實際情況,我公司經過(guo)攻關(guan),*終研制(zhi)出一種(zhong)利用(yong)新試驗方(fang)法(fa)進行測量(liang)的儀(yi)器(qi)(qi)(qi),這就是(shi)三相電(dian)容(rong)電(dian)感(gan)測試儀(yi)。該儀(yi)器(qi)(qi)(qi)可(ke)以(yi)在不拆線(xian)的狀態下,測量(liang)成組(zu)并聯(lian)電(dian)容(rong)器(qi)(qi)(qi)的單(dan)相電(dian)容(rong)或各種(zhong)組(zu)合連(lian)接類型的三相電(dian)容(rong)器(qi)(qi)(qi),同(tong)時也能夠測量(liang)各種(zhong)電(dian)抗(kang)器(qi)(qi)(qi)的電(dian)感(gan),本儀(yi)器(qi)(qi)(qi)還能測量(liang)工頻狀況下的電(dian)流(liu),該儀(yi)器(qi)(qi)(qi)接線(xian)方(fang)便,操作簡單(dan),減輕了檢修人員(yuan)的工作負擔,大大提(ti)高了現(xian)場的測試效率,為(wei)電(dian)網的正常運行提(ti)供了**保障。
二、WBDG-2000三相電(dian)容電(dian)感測試儀功能特(te)點
本(ben)儀器(qi)(qi)可(ke)在(zai)不拆線情(qing)況下(xia)測(ce)量成組并(bing)聯(lian)電容(rong)器(qi)(qi)的(de)單個單相電容(rong)及同(tong)時(shi)測(ce)量各種(zhong)連接類型的(de)三(san)相電容(rong),同(tong)時(shi)本(ben)儀器(qi)(qi)也能(neng)測(ce)量各種(zhong)電抗(kang)器(qi)(qi)的(de)電感量,還可(ke)以(yi)做(zuo)為工頻電流測(ce)試儀使用(yong),一機三(san)用(yong),滿足現場(chang)的(de)多種(zhong)使用(yong);
測量時本儀器顯示測量電(dian)容(rong)值或(huo)電(dian)感值的(de)(de)同時還可以顯示測量的(de)(de)電(dian)壓、電(dian)流、功(gong)率、頻率、阻抗、相位角(jiao)等數(shu)據,以便(bian)更好的(de)(de)分(fen)析試(shi)品的(de)(de)好壞(huai);
儀器采用(yong)240×128大屏幕(mu)帶(dai)背光的(de)液(ye)晶顯示,白天夜間均能(neng)清晰觀察(cha),中文菜單提示,操(cao)作(zuo)簡(jian)便;
儀(yi)器內置大容量非易(yi)失(shi)性存(cun)儲器:可(ke)存(cun)儲50組測量數據;
儀器內置(zhi)高(gao)精度實時(shi)時(shi)鐘功能(neng):可進(jin)行日期(qi)及時(shi)間校準;
儀器自帶高速(su)微型熱敏打印(yin)機(ji):可打印(yin)測(ce)量及歷史數據;
儀器試驗(yan)電源過流保護(hu)功能:電源輸出(chu)短路不會損壞儀器。
三、WBDG-2000三相電容電感測試(shi)儀(yi)技術指標
輸出(chu)電壓 ~2V, ~20V
輸出電流: ≤10A
測量范(fan)圍
電容:0.1uF~2000uF
電感:0.1mH~10H
電流(liu):1mA~10A
電壓: 0 ~25V
測量精度
電容(rong):±(1%+2字)
電感:±(1%+5字)
電流:±(1%+2字)
電壓(ya):±(1%+2字)
外(wai)形尺寸(cun) 350mm×230mm×190mm
儀(yi)器重量 8kg
四、WBDG-2000三相電容電感測試儀使(shi)用條件
環(huan)境溫度(du) -10℃~50℃
環境濕度 ≤85%RH
工作(zuo)電(dian)源(yuan) AC220V±10%
電源頻率 50±1Hz
儀器(qi)功率 200W
五、WBDG-2000三相電容電感測(ce)試儀面板介紹
Ua、Ub、Uc、Uo:測試線(xian)電源電壓(ya)輸出端;
ua、ub、uc、 uo :測試線(xian)采樣電(dian)壓引入端;
Ia、Ib、Ic:電流鉗接線引(yin)入端;
電源(yuan)(yuan)開(kai)關:接(jie)通和斷開(kai)交流電源(yuan)(yuan);
FUSE : 保險盒(he)
:儀(yi)器(qi)接地端子
液(ye) 晶 屏(ping):顯示操作提示及(ji)測(ce)量數據(ju)
鍵 盤:儀器各種(zhong)功能(neng)的操作
打(da) 印 機:打(da)印各種測量數(shu)據
六、操作說(shuo)明
當儀(yi)器按(an)要求接好測(ce)試線及電源線后,打開電源開關,液晶(jing)顯(xian)示開機(ji)界面,如下圖:
延時兩三秒鐘后液晶顯示(shi)主菜單,如下圖(tu)所示(shi):
如(ru)果需(xu)要電(dian)容測試(shi),在(zai)主菜單畫面(mian)下,按↑ ↓鍵,選擇 電(dian)容測試(shi) 后,按 確(que)認(ren) 鍵,進入電(dian)容測量(liang)設定(ding)畫面(mian),如(ru)下圖所(suo)示:
在電容(rong)測量界面,按↑ ↓鍵(jian)選(xuan)擇被測電容(rong)類型,按 確認 鍵(jian)進入如下顯示界面(選(xuan)擇單相電容(rong)):
經(jing)過幾秒(miao)鐘時間,顯示測試結果如下圖(tu)所示:
如(ru)果要打印數(shu)據,請按(an)(an)打印鍵,存儲數(shu)據請按(an)(an)F1鍵(jian),如果(guo)還需(xu)測(ce)量同相(xiang)電(dian)壓下(xia)的其他單相(xiang)電(dian)容,可按返回鍵(jian)返回電(dian)容測(ce)試界面(mian),將(jiang)電(dian)流鉗夾(jia)到被測(ce)電(dian)容上(shang),按確認鍵(jian)重新(xin)測(ce)量。
在(zai)電(dian)(dian)容(rong)(rong)測(ce)(ce)量界(jie)面,如(ru)果要測(ce)(ce)試(shi)三(san)相電(dian)(dian)容(rong)(rong),首(shou)先(xian)根據(ju)連接類型將(jiang)所(suo)需測(ce)(ce)試(shi)線連接好,請(qing)按(an)↑ ↓鍵選(xuan)擇被測(ce)(ce)三(san)相電(dian)(dian)容(rong)(rong)類型,比如(ru)如(ru)果選(xuan)擇三(san)相△型電(dian)(dian)容(rong)(rong)測(ce)(ce)試(shi),屏幕顯示的界(jie)面如(ru)下圖所(suo)示:
按 確(que)認 鍵(jian)進入如下(xia)顯示界面:
經(jing)過一段時間(jian),顯示測試(shi)結(jie)果如(ru)下圖所(suo)示:
存儲數(shu)據請(qing)按F1鍵(jian)(jian),打(da)印數(shu)據請(qing)按(an)打(da)印鍵(jian)(jian),按(an)返回鍵(jian)(jian)返回電容測試界面(mian),其他連接類(lei)型(xing)的三(san)相電容測試方法與(yu)上類(lei)同。按(an)返回鍵(jian)(jian)或復位鍵(jian)(jian)可回到主菜(cai)單。
電感測(ce)試(shi)及電流測(ce)試(shi)與電容測(ce)試(shi)操作類同,不再(zai)重復介紹。
如果需(xu)要(yao)設(she)置時間(jian)(jian)可按(an)← →及↑ ↓鍵,選中時間(jian)(jian)設(she)置,按(an)確認鍵進(jin)入設(she)置界面如下:
按← →改變(bian)光(guang)標前后位置,按↑ ↓鍵改變(bian)光(guang)標處當前值的(de)大小,設置完(wan)成(cheng)可按返(fan)回鍵或(huo)復(fu)位鍵返(fan)回主菜單。
參數設置(zhi)為出廠校準時(shi)設置(zhi),建議客戶不得改(gai)變其設置(zhi)數據(ju),否則會造成測(ce)試(shi)數據(ju)的(de)不準。如果需要重新更(geng)改(gai),必(bi)須在本公司技術人員指導下進行,并且(qie)先要記錄(lu)下更(geng)改(gai)前的(de)設定值(zhi)(zhi),以便設置(zhi)失敗時(shi)能夠恢復初(chu)始值(zhi)(zhi)。
如果想查詢已存(cun)儲的(de)記錄,可在主(zhu)菜單下選擇查詢記錄,按確(que)認鍵進(jin)入顯(xian)示如下:
按(an)↑ ↓鍵(jian)查詢所(suo)需(xu)記(ji)錄(lu),按(an)打(da)印鍵(jian)可打(da)印當前記(ji)錄(lu),如果要刪(shan)除記(ji)錄(lu),可按(an)F2鍵(jian)(jian)進行刪除,刪除完成后所有記錄均(jun)清零。按返(fan)回鍵(jian)(jian)或(huo)復位(wei)鍵(jian)(jian)可(ke)返(fan)回主菜單。
測試(shi)數據(ju)中(zhong)各符號的含義:
⑴、I:被測電容(rong)(抗)器的電流有(you)效值,單(dan)位為(wei)A(安培);
⑵、U:被測電(dian)容(抗)器(qi)的(de)電(dian)壓有效(xiao)值(zhi),單位為(wei)V(伏特(te));
⑶、P:被測電容(抗(kang))器的有(you)功功率有(you)效值(zhi),單位為W(瓦);
⑷、F:輸出電源的當前頻率,單位為Hz(赫茲);
⑸、Rc:被測電容器的容抗,單位為Ω(歐姆(mu));
⑹、Rl:被測(ce)電抗器的(de)感(gan)抗,單位為Ω(歐姆);
⑺、Rz:被測試品的阻抗,單位(wei)為Ω(歐姆);
⑻、C:被測試電(dian)容(rong)器的電(dian)容(rong)值,單(dan)位為uF(微(wei)法);
⑼、Cab:被測三相電(dian)容(rong)器的AB相電容值,單位為uF(微(wei)法(fa));
⑽、Cbc:被測三相電容(rong)器的(de)BC相電容值,單位為uF(微法);
⑾、Cca:被測三相電容(rong)器的CA相電容值,單位為uF(微(wei)法);
⑿、Ca:被(bei)測三相電容器的A相(xiang)電容值(zhi),單(dan)位(wei)為uF(微法);
⒀、Cb:被測三相電容器的(de)B相電容值,單位為uF(微法(fa));
⒁、Cc:被(bei)測(ce)三相電(dian)容器的C相電容值(zhi),單位(wei)為uF(微法);
⒂、Cz:被測(ce)三相(xiang)電(dian)容器總的(de)電(dian)容值,單位為(wei)uF(微法);
⒃、L:被測電抗器的(de)當(dang)前測量電感值,單位為H(亨);
⒄、Ф:被(bei)測試(shi)品的(de)電壓與電流之間的(de)相位角,單位為 o(度(du))
七(qi)、測試接線(xian)
單相電(dian)容的測量:
單(dan)相電(dian)容測試時,將紅(hong)測試線一端接在(zai)Ua、ua上(shang),另一(yi)端測(ce)試鉗接(jie)在一(yi)條母線(xian)上(shang),黑(hei)測(ce)試線(xian)一(yi)端接(jie)在Uo、uo上,另一端(duan)接在另一條(tiao)母線上,鉗形(xing)CT輸出(chu)線接(jie)到(dao)儀(yi)器Ia端,鉗形CT夾在與紅測試鉗相連母線(xian)的電容(rong)引入端,連線(xian)時要注(zhu)意電流鉗上標(biao)有“P”的一端朝向(xiang)電容方向(xiang)夾在電容器上,否則測試的相位角不正確。
如果電(dian)容器組有多個單相電(dian)容需要測試(shi)(shi)(shi)(shi),可以在(zai)測試(shi)(shi)(shi)(shi)完**個電(dian)容值后(hou)按返回鍵(jian),電(dian)壓測試(shi)(shi)(shi)(shi)線不(bu)用動,直接(jie)將(jiang)測試(shi)(shi)(shi)(shi)電(dian)流的電(dian)流鉗(qian)打(da)開然后(hou)夾到下一個電(dian)容上按確(que)認(ren)鍵(jian)進行測試(shi)(shi)(shi)(shi),這樣可大(da)大(da)的提(ti)高測試(shi)(shi)(shi)(shi)速度,這才是本儀(yi)器的*大(da)特色。
(2)三(san)相(xiang)△型電容的測量:
圖13是(shi)三相△形電(dian)容(rong)測(ce)量接線(xian)方(fang)法,測(ce)量線(xian)由儀器(qi)測(ce)量輸出(chu)端按顏色對應接好,將紅(hong)色夾子夾在母(mu)線(xian)排A相上、綠色夾子夾在母線(xian)B相上,紅色夾(jia)子(zi)夾(jia)在母線C上,然后(hou)將三(san)個電流測量線分(fen)別對(dui)應插在儀器Ia、Ib、Ic上擰緊、鉗形傳感器(qi)對應套在高壓電容器(qi)組(zu)A相、B相(xiang)、C相引入線(xian)上,要(yao)注意各鉗型(xing)電(dian)流互(hu)感器的(de)方(fang)向是(shi)否(fou)正確(que),否(fou)則會造成所(suo)測(ce)電(dian)容(rong)的(de)相位角(jiao)錯誤。
(3)三相Y型電容的(de)測量(liang):
三相Y型電容(rong)與△形(xing)聯接電容(rong)器的接線方法一(yi)樣,只是測量時選擇三相Y型(xing)電(dian)容測量。這里(li)不再做具體介(jie)紹。
(4)三相Yn型電容的測(ce)量(liang):
圖14是三(san)相Yn型電容測(ce)量接(jie)(jie)線方法,測(ce)量線由儀(yi)器測(ce)量輸出(chu)端按顏(yan)色對應接(jie)(jie)好,將紅(hong)色夾(jia)子(zi)夾(jia)在(zai)母(mu)線排A相上、綠(lv)色(se)夾子夾在母線(xian)B相上,紅色夾(jia)(jia)子夾(jia)(jia)在母線C上,黑(hei)色夾子(zi)夾在母(mu)線(xian)N上,然后將三個電流(liu)測量線分(fen)別對應插(cha)在儀器Ia、Ib、Ic上擰緊、鉗形傳(chuan)感器對應套在(zai)高壓電(dian)容器組A相、B相(xiang)、C相(xiang)(xiang)引入(ru)線上,要注意各(ge)鉗型電(dian)流互感器(qi)的(de)(de)方向(xiang)是否正確,否則(ze)會造(zao)成所測電(dian)容(rong)的(de)(de)相(xiang)(xiang)位角錯(cuo)誤。
(5)三相III型(xing)電(dian)容(rong)的(de)測量:
圖15為三(san)相Ⅲ型電容(rong)器測(ce)量(liang)(liang)接線(xian)(xian)方(fang)法,測(ce)量(liang)(liang)線(xian)(xian)由儀器測(ce)量(liang)(liang)輸出端按顏色對應插好,將黃色夾(jia)子夾(jia)在母線(xian)(xian)排A相上,將(jiang)綠色夾子夾在母線排B相上,將紅色夾(jia)子夾(jia)在母線(xian)排C相上,黑色夾(jia)子夾(jia)在A’線上,將A‘B’C‘短接(jie),然后將三個電流測(ce)量線分別對應(ying)插在(zai)儀器Ia、Ib、Ic上擰緊、鉗形傳感器對應套(tao)在(zai)高壓電容器組A相、B相(xiang)、C相引(yin)入線上(shang)。
(6)電(dian)(dian)抗器(qi)電(dian)(dian)感的測量(liang):
電抗器電感(gan)測試(shi)時,將紅測試(shi)線一端接在Ua、ua上(shang)(shang),另一(yi)端(duan)(duan)測(ce)(ce)試鉗接(jie)在(zai)電抗器一(yi)引(yin)出(chu)端(duan)(duan)上(shang)(shang),黑(hei)測(ce)(ce)試線一(yi)端(duan)(duan)接(jie)在(zai)Uo、uo上(shang),另(ling)一端接(jie)在電抗器另(ling)一引出端上(shang),鉗形CT輸出線(xian)接到儀器Ia端,鉗形(xing)CT夾在與紅測試鉗相(xiang)連電抗(kang)器(qi)引出端,連線(xian)時要(yao)注(zhu)意電流(liu)鉗上標有“P”的一端朝向電(dian)(dian)抗器方向夾(jia)在電(dian)(dian)抗器上(shang),否則測試的相(xiang)位角不(bu)正(zheng)確。
八(ba)、產品成(cheng)套(tao)性:
部 件
|
數量(liang)
|
部 件
|
數量
|
電容電感測試儀主(zhu)機
|
1臺
|
鉗形電流傳(chuan)感器
|
3個
|
測試線
|
1套(tao)
|
5A保險管(guan)250V
|
2個
|
儀(yi)器電(dian)源線
|
1根
|
產品出廠合格(ge)證
|
1張(zhang)
|
儀器(qi)使用說(shuo)明(ming)書
|
1本
|
接地(di)線
|
1條
|
保(bao)修卡
|
1張
|
打(da)印紙
|
2卷
|
|
|
裝箱單
|
1張
|
用戶(hu)收到儀器后,按照儀器的成套說明,開箱檢查(cha)是否相(xiang)符(fu),核對上述內容,若發生缺少,請(qing)立即與本(ben)公司聯系。
九(jiu)、注意事(shi)項
8.1使(shi)用(yong)本儀器前(qian)請(qing)仔細閱(yue)讀使(shi)用(yong)說明書,檢查接線(xian)無誤(wu)、接地良好。
8.2高(gao)(gao)精度(du)電流鉗為本儀器測量的關鍵部件,受損后(hou)對(dui)測試數據(ju)有很大的影(ying)響,在(zai)使用過程(cheng)中需謹慎,要輕拿(na)輕放,不能從高(gao)(gao)空掉落或(huo)者摔碰(peng)。
8.3在(zai)測量(liang)(liang)完畢并退出測量(liang)(liang)狀態后,關閉儀器電(dian)源,方可進(jin)行接(jie)線拆除。
8 .4如出現無法(fa)解決的問題,請及時與本(ben)公司取得聯系(xi)。
十、售后(hou)服務
儀器自(zi)購(gou)買(mai)之(zhi)日起一(yi)年內(nei),屬產品質量問題免費包修包換(huan),終身提供維(wei)修和(he)技(ji)術(shu)服(fu)務。如發現儀器有異常情況(kuang)或故障請與公(gong)司(si)及時聯系(xi),以便為您安排*便捷的處理方(fang)案。