一、WBDG-2000三相型電(dian)容電(dian)感值分析儀產品概(gai)述(shu)
無(wu)功(gong)(gong)補(bu)(bu)償電(dian)(dian)(dian)容(rong)(rong)(rong)器(qi)(qi)(qi)(qi)是(shi)(shi)滿足電(dian)(dian)(dian)力(li)系統無(wu)功(gong)(gong)平衡的(de)重(zhong)要(yao)設備。近年來無(wu)功(gong)(gong)問題得(de)到(dao)了電(dian)(dian)(dian)業部門(men)的(de)普遍重(zhong)視,無(wu)功(gong)(gong)補(bu)(bu)償成(cheng)(cheng)套裝置已大(da)量(liang)(liang)(liang)投(tou)(tou)入配電(dian)(dian)(dian)網運行(xing)。電(dian)(dian)(dian)能(neng)供(gong)給要(yao)求系統有功(gong)(gong)與無(wu)功(gong)(gong)實(shi)時(shi)平衡。因此(ci),無(wu)功(gong)(gong)補(bu)(bu)償裝置應滿足自動(dong)跟(gen)蹤、實(shi)時(shi)補(bu)(bu)償的(de)要(yao)求,這就不可避免(mian)地要(yao)頻繁投(tou)(tou)、切無(wu)功(gong)(gong)補(bu)(bu)償電(dian)(dian)(dian)容(rong)(rong)(rong)器(qi)(qi)(qi)(qi)組(zu)。電(dian)(dian)(dian)容(rong)(rong)(rong)器(qi)(qi)(qi)(qi)組(zu)的(de)投(tou)(tou)、切操作,就會產(chan)生過(guo)電(dian)(dian)(dian)流與過(guo)電(dian)(dian)(dian)壓(ya)沖擊,引起電(dian)(dian)(dian)容(rong)(rong)(rong)器(qi)(qi)(qi)(qi)損壞。為保證設備的(de)可靠(kao)性,早期發(fa)現(xian)電(dian)(dian)(dian)容(rong)(rong)(rong)器(qi)(qi)(qi)(qi)缺陷,避免(mian)故障(zhang)擴(kuo)大(da),需要(yao)定期進行(xing)檢(jian)(jian)測(ce)。而在現(xian)場電(dian)(dian)(dian)容(rong)(rong)(rong)器(qi)(qi)(qi)(qi)都是(shi)(shi)成(cheng)(cheng)組(zu)并聯的(de),傳統方(fang)法(fa)是(shi)(shi)將(jiang)電(dian)(dian)(dian)容(rong)(rong)(rong)匯流排拆(chai)除(chu),然后(hou)用老(lao)式(shi)電(dian)(dian)(dian)容(rong)(rong)(rong)表進行(xing)測(ce)量(liang)(liang)(liang),由于電(dian)(dian)(dian)容(rong)(rong)(rong)器(qi)(qi)(qi)(qi)組(zu)是(shi)(shi)由幾十(shi)至上百個(ge)小電(dian)(dian)(dian)容(rong)(rong)(rong)器(qi)(qi)(qi)(qi)組(zu)成(cheng)(cheng),要(yao)拆(chai)線(xian)測(ce)量(liang)(liang)(liang)電(dian)(dian)(dian)容(rong)(rong)(rong)量(liang)(liang)(liang)的(de)工作量(liang)(liang)(liang)很大(da),而且經常拆(chai)線(xian)會使得(de)螺絲(si)滑牙或沒有上緊而留下**隱患,也容(rong)(rong)(rong)易造成(cheng)(cheng)電(dian)(dian)(dian)容(rong)(rong)(rong)的(de)二次損壞。因此(ci),非(fei)常期望有一種測(ce)試儀器(qi)(qi)(qi)(qi)不用拆(chai)線(xian)就能(neng)測(ce)量(liang)(liang)(liang)各個(ge)小電(dian)(dian)(dian)容(rong)(rong)(rong)器(qi)(qi)(qi)(qi)的(de)電(dian)(dian)(dian)容(rong)(rong)(rong)量(liang)(liang)(liang),減(jian)輕檢(jian)(jian)修人(ren)員(yuan)的(de)負擔(dan),提高檢(jian)(jian)修工作的(de)效率,提高配電(dian)(dian)(dian)網運行(xing)的(de)**性。
針對現(xian)場(chang)的實際情況,我公(gong)司(si)經過攻關(guan),*終研制出一(yi)種(zhong)(zhong)利(li)用新試(shi)驗方法進行測(ce)(ce)量的儀器,這(zhe)就(jiu)是(shi)三相(xiang)電(dian)(dian)容(rong)電(dian)(dian)感(gan)測(ce)(ce)試(shi)儀。該儀器可(ke)以在不拆線(xian)的狀(zhuang)態(tai)下(xia),測(ce)(ce)量成組并聯電(dian)(dian)容(rong)器的單相(xiang)電(dian)(dian)容(rong)或(huo)各種(zhong)(zhong)組合連接類型的三相(xiang)電(dian)(dian)容(rong)器,同時也能(neng)(neng)夠(gou)測(ce)(ce)量各種(zhong)(zhong)電(dian)(dian)抗器的電(dian)(dian)感(gan),本儀器還能(neng)(neng)測(ce)(ce)量工頻狀(zhuang)況下(xia)的電(dian)(dian)流,該儀器接線(xian)方便,操作(zuo)簡單,減(jian)輕了(le)檢修人(ren)員的工作(zuo)負擔,大大提高了(le)現(xian)場(chang)的測(ce)(ce)試(shi)效率,為電(dian)(dian)網(wang)的正常運行提供了(le)**保障。
二、WBDG-2000三相型電容(rong)電感值分析儀功能特點
本儀器可在不(bu)拆線情況(kuang)下(xia)測(ce)量(liang)成組并聯(lian)電(dian)(dian)容器的單(dan)個單(dan)相(xiang)電(dian)(dian)容及同時測(ce)量(liang)各種連接(jie)類型的三相(xiang)電(dian)(dian)容,同時本儀器也能測(ce)量(liang)各種電(dian)(dian)抗器的電(dian)(dian)感量(liang),還可以(yi)做為工頻電(dian)(dian)流測(ce)試儀使用(yong)(yong),一機三用(yong)(yong),滿(man)足現場的多種使用(yong)(yong);
測(ce)(ce)量時(shi)本儀(yi)器顯示測(ce)(ce)量電容值(zhi)或電感(gan)值(zhi)的(de)同時(shi)還可以顯示測(ce)(ce)量的(de)電壓(ya)、電流(liu)、功率、頻率、阻抗、相(xiang)位角(jiao)等(deng)數據,以便更好的(de)分析試品的(de)好壞(huai);
儀器采用240×128大屏(ping)幕(mu)帶背光(guang)的液晶顯示,白(bai)天夜間(jian)均能(neng)清晰觀察,中文菜單提(ti)示,操作簡便;
儀器內置(zhi)大容量非易失性存儲器:可(ke)存儲50組測(ce)量(liang)數據(ju);
儀器內置高精度實時(shi)時(shi)鐘功能(neng):可進行(xing)日期及(ji)時(shi)間校準;
儀(yi)器自帶高速微型熱(re)敏打(da)印機(ji):可打(da)印測(ce)量(liang)及歷史數據;
儀(yi)器試驗電源過流保護功(gong)能:電源輸(shu)出短路不會(hui)損壞儀(yi)器。
三、WBDG-2000三相(xiang)型電容電感(gan)值分析(xi)儀技術指標(biao)
輸出電壓 ~2V, ~20V
輸出(chu)電(dian)流: ≤10A
測量范(fan)圍(wei)
電容:0.1uF~2000uF
電(dian)感:0.1mH~10H
電流(liu):1mA~10A
電壓: 0 ~25V
測(ce)量精度
電(dian)容:±(1%+2字)
電感:±(1%+5字)
電(dian)流:±(1%+2字)
電壓:±(1%+2字)
外形尺寸(cun) 350mm×230mm×190mm
儀器重量 8kg
四、WBDG-2000三相型電容電感值分析儀使用條件(jian)
環境(jing)溫(wen)度 -10℃~50℃
環(huan)境濕度 ≤85%RH
工作(zuo)電源 AC220V±10%
電源頻(pin)率 50±1Hz
儀器功率 200W
五、WBDG-2000三相型電容(rong)電感值分析儀面(mian)板(ban)介紹
Ua、Ub、Uc、Uo:測(ce)試線電源電壓輸出端;
ua、ub、uc、 uo :測試線(xian)采樣電壓(ya)引入端;
Ia、Ib、Ic:電(dian)流鉗(qian)接(jie)線引入端;
電(dian)源(yuan)開關(guan):接通和斷開交流(liu)電(dian)源(yuan);
FUSE : 保險盒
:儀器接地端子
液 晶 屏:顯示操作提示及測量數據(ju)
鍵 盤:儀(yi)器各種(zhong)功能的操作(zuo)
打 印(yin) 機:打印(yin)各種測量數據
六、操作說明
當(dang)儀器按要求接(jie)好(hao)測(ce)試(shi)線及電源線后,打(da)開電源開關,液晶(jing)顯(xian)示開機界面(mian),如(ru)下圖:
延(yan)時(shi)兩三秒鐘后液晶顯(xian)示主菜單,如下圖(tu)所(suo)示:
如果需要電容測試(shi),在主菜單畫(hua)面下,按↑ ↓鍵,選擇 電容測試(shi) 后,按 確認 鍵,進入電容測量設定畫(hua)面,如下圖所示:
在(zai)電容(rong)測量界(jie)面(mian),按↑ ↓鍵選(xuan)擇(ze)被測電容(rong)類型,按 確認 鍵進入(ru)如下顯(xian)示界(jie)面(mian)(選(xuan)擇(ze)單相(xiang)電容(rong)):
經過幾秒鐘時間,顯示測(ce)試結果如下(xia)圖所(suo)示:
如(ru)果要打印數據,請按(an)(an)打印鍵,存儲數據請按(an)(an)F1鍵,如果還需測(ce)量同(tong)相(xiang)電(dian)壓下的其他單相(xiang)電(dian)容,可按(an)返回鍵返回電(dian)容測(ce)試界面,將電(dian)流鉗夾(jia)到被測(ce)電(dian)容上(shang),按(an)確(que)認鍵重新測(ce)量。
在(zai)電(dian)容(rong)(rong)測(ce)量(liang)界面,如果要(yao)測(ce)試(shi)三(san)相(xiang)電(dian)容(rong)(rong),首先根據(ju)連接(jie)類(lei)型將所(suo)需(xu)測(ce)試(shi)線連接(jie)好,請(qing)按↑ ↓鍵選擇被測(ce)三(san)相(xiang)電(dian)容(rong)(rong)類(lei)型,比如如果選擇三(san)相(xiang)△型電(dian)容(rong)(rong)測(ce)試(shi),屏幕(mu)顯示(shi)的界面如下(xia)圖所(suo)示(shi):
按(an) 確認 鍵進(jin)入如下顯示界面:
經過(guo)一(yi)段時(shi)間,顯示測試結果如下圖所示:
存儲數(shu)據請按F1鍵(jian),打印數(shu)據請按(an)打印鍵(jian),按(an)返回鍵(jian)返回電容測試界(jie)面,其他(ta)連接類型(xing)的三相(xiang)電容測試方法與上(shang)類同。按(an)返回鍵(jian)或復位鍵(jian)可回到主菜單。
電(dian)感(gan)測(ce)試及電(dian)流測(ce)試與電(dian)容(rong)測(ce)試操作類同(tong),不再重復介紹。
如果需要設置(zhi)時(shi)間可按(an)← →及↑ ↓鍵,選(xuan)中時(shi)間設置(zhi),按(an)確認鍵進入設置(zhi)界面(mian)如下:
按← →改(gai)變光標前后(hou)位(wei)置,按↑ ↓鍵改(gai)變光標處當(dang)前值的大(da)小,設置完成可按返回鍵或復位(wei)鍵返回主菜(cai)單(dan)。
參數設置為出廠(chang)校準(zhun)時設置,建(jian)議客(ke)戶不(bu)得(de)改(gai)變其設置數據,否則會造成測試數據的(de)不(bu)準(zhun)。如果需要(yao)重新(xin)更改(gai),必須在本公司技術人(ren)員(yuan)指導下進行,并且先要(yao)記錄(lu)下更改(gai)前的(de)設定值(zhi),以便設置失敗時能(neng)夠恢復初始值(zhi)。
如果(guo)想(xiang)查(cha)詢已存儲的記(ji)錄,可在主菜單下(xia)選擇查(cha)詢記(ji)錄,按確認鍵進入顯示如下(xia):
按↑ ↓鍵查詢(xun)所需記錄(lu),按打印(yin)(yin)鍵可打印(yin)(yin)當前記錄(lu),如(ru)果要刪除記錄(lu),可按F2鍵進行刪(shan)除(chu),刪(shan)除(chu)完成(cheng)后所有記錄均(jun)清零。按返(fan)回鍵或復位鍵可返(fan)回主菜(cai)單。
測(ce)試數據中(zhong)各(ge)符號的含義:
⑴、I:被(bei)測電容(抗)器的電流有效(xiao)值,單位為A(安培);
⑵、U:被測電(dian)(dian)容(抗)器的電(dian)(dian)壓有效(xiao)值,單位為V(伏特(te));
⑶、P:被測電容(rong)(抗)器的有功功率(lv)有效(xiao)值(zhi),單(dan)位為(wei)W(瓦);
⑷、F:輸出(chu)電源的當前(qian)頻(pin)率,單位為Hz(赫茲);
⑸、Rc:被(bei)測電容器(qi)的容抗,單位為Ω(歐姆);
⑹、Rl:被測電(dian)抗(kang)器的(de)感抗(kang),單位為Ω(歐(ou)姆);
⑺、Rz:被測試品的阻(zu)抗,單位為Ω(歐姆);
⑻、C:被測試電(dian)容(rong)(rong)器的電(dian)容(rong)(rong)值,單(dan)位為uF(微法);
⑼、Cab:被(bei)測三(san)相電容器(qi)的(de)AB相(xiang)電容值(zhi),單位(wei)為uF(微法);
⑽、Cbc:被測三相電容器(qi)的BC相電(dian)容(rong)值,單(dan)位(wei)為uF(微法);
⑾、Cca:被測三相電容器的(de)CA相電容值,單(dan)位為uF(微法);
⑿、Ca:被測三相(xiang)電容(rong)器的A相電容值,單位為uF(微(wei)法);
⒀、Cb:被測三相電(dian)容器的B相電容值(zhi),單位為uF(微(wei)法);
⒁、Cc:被測(ce)三(san)相(xiang)電容器的C相電容值,單位為uF(微法);
⒂、Cz:被測三(san)相電(dian)容器總的(de)電(dian)容值,單(dan)位(wei)為(wei)uF(微(wei)法);
⒃、L:被測電抗(kang)器(qi)的當前(qian)測量電感值,單位為H(亨);
⒄、Ф:被測試(shi)品的電(dian)壓與電(dian)流之間(jian)的相位(wei)角,單位(wei)為 o(度)
七、測(ce)試接線
單相電容的(de)測量:
單(dan)相電容測(ce)試時,將紅(hong)測(ce)試線一端接在Ua、ua上,另(ling)一端(duan)測試鉗接(jie)在一條母線上,黑(hei)測試線一端(duan)接(jie)在Uo、uo上,另一(yi)端接在另一(yi)條母(mu)線上,鉗形(xing)CT輸(shu)出線(xian)接到(dao)儀器Ia端,鉗形CT夾在與紅(hong)測試鉗相連母線的電容引入端,連線時(shi)要注意(yi)電流鉗上標有(you)“P”的(de)一(yi)端朝向電容方向夾(jia)在電容器上,否則測試的(de)相位角不正確。
如(ru)果電容(rong)器組有多個單(dan)相電容(rong)需要測(ce)試(shi)(shi)(shi)(shi),可以在測(ce)試(shi)(shi)(shi)(shi)完**個電容(rong)值(zhi)后按返回(hui)鍵,電壓測(ce)試(shi)(shi)(shi)(shi)線不用動,直接將測(ce)試(shi)(shi)(shi)(shi)電流的電流鉗(qian)打開然后夾到下一個電容(rong)上按確認鍵進行測(ce)試(shi)(shi)(shi)(shi),這樣(yang)可大大的提(ti)高測(ce)試(shi)(shi)(shi)(shi)速(su)度,這才是本儀器的*大特色(se)。
(2)三(san)相△型(xing)電容(rong)的測量(liang):
圖13是(shi)三相(xiang)△形電容測量接線方(fang)法,測量線由儀器測量輸出端按顏色對應接好(hao),將紅色夾(jia)子(zi)夾(jia)在母(mu)線排A相上、綠色夾子夾在母線B相上,紅色(se)夾(jia)子夾(jia)在母線C上,然后將三個電(dian)流測量線分別對應插在儀器Ia、Ib、Ic上(shang)擰緊、鉗(qian)形傳感器對應套在高壓(ya)電容器組A相、B相(xiang)、C相(xiang)引入(ru)線(xian)上,要注意各鉗型電流互感(gan)器的(de)方向是(shi)否(fou)正確,否(fou)則會(hui)造成所(suo)測電容的(de)相(xiang)位角錯誤。
(3)三相Y型電容的測量(liang):
三相Y型電容與△形聯接電容器(qi)的接線(xian)方法一樣,只是測量時(shi)選擇(ze)三相Y型電容測量。這(zhe)里不再(zai)做具體(ti)介紹。
(4)三相Yn型電容的測量:
圖14是三(san)相(xiang)Yn型(xing)電容測量接(jie)線(xian)方法,測量線(xian)由儀器測量輸出端(duan)按顏色(se)對應接(jie)好,將紅色(se)夾(jia)子夾(jia)在(zai)母線(xian)排A相上、綠色夾(jia)(jia)子夾(jia)(jia)在(zai)母線B相上,紅色夾子(zi)夾在母(mu)線C上,黑色夾子(zi)夾在母線N上(shang),然后將三個電流測量線分別對應插在儀器(qi)Ia、Ib、Ic上擰緊、鉗形(xing)傳(chuan)感器(qi)對應套在(zai)高壓電容器(qi)組(zu)A相(xiang)、B相(xiang)、C相(xiang)引(yin)入線(xian)上,要注(zhu)意各鉗型電(dian)流互感(gan)器的方向是否正確,否則(ze)會造成所測(ce)電(dian)容的相(xiang)位角錯誤。
(5)三相III型電容(rong)的測量:
圖15為三相(xiang)Ⅲ型電容(rong)器(qi)測(ce)量(liang)接線(xian)方法(fa),測(ce)量(liang)線(xian)由儀器(qi)測(ce)量(liang)輸出端(duan)按顏色對應插好,將黃色夾子(zi)夾在(zai)母線(xian)排A相上,將綠色(se)夾子夾在母線排B相上,將(jiang)紅色夾子夾在母線排C相上,黑色夾子夾在A’線(xian)上,將A‘B’C‘短接,然后將三個電(dian)流測(ce)量線(xian)分別(bie)對應插在儀器Ia、Ib、Ic上擰緊(jin)、鉗形傳感(gan)器(qi)對應套(tao)在高壓電容器(qi)組A相、B相、C相引入線上(shang)。
(6)電抗(kang)器(qi)電感的測量:
電抗(kang)器電感測試時,將紅測試線一端接(jie)在Ua、ua上(shang),另(ling)一端(duan)測試(shi)鉗(qian)接在電抗器一引出端(duan)上(shang),黑(hei)測試(shi)線一端(duan)接在Uo、uo上,另一(yi)端接在電抗器另一(yi)引出(chu)端上,鉗形CT輸出線(xian)接到儀器(qi)Ia端,鉗(qian)形CT夾在與紅測試鉗(qian)相連(lian)電抗(kang)器引(yin)出端,連(lian)線時要注意(yi)電流鉗(qian)上標有“P”的一(yi)端朝(chao)向電抗器方向夾在(zai)電抗器上,否則測試的相位角不正確。
八、產品成套性:
部 件
|
數量(liang)
|
部 件
|
數量
|
電容電感測試儀主機
|
1臺(tai)
|
鉗形電流傳(chuan)感器
|
3個
|
測(ce)試線
|
1套
|
5A保險管250V
|
2個(ge)
|
儀(yi)器電源(yuan)線(xian)
|
1根
|
產品(pin)出廠合格證
|
1張(zhang)
|
儀器使(shi)用說明書
|
1本
|
接(jie)地線
|
1條
|
保修(xiu)卡(ka)
|
1張
|
打印紙
|
2卷
|
|
|
裝(zhuang)箱(xiang)單
|
1張
|
用戶收到儀器(qi)后,按照儀器(qi)的(de)成套(tao)說明,開箱(xiang)檢查是否相(xiang)符,核對上(shang)述內容,若發生缺少,請(qing)立即與本公(gong)司聯(lian)系。
九、注意事項
8.1使用(yong)本儀器前請仔細(xi)閱(yue)讀使用(yong)說明書,檢查(cha)接線無誤(wu)、接地良好(hao)。
8.2高精度電流鉗為本儀器測(ce)量的關鍵部(bu)件,受損后對測(ce)試數據有很(hen)大(da)的影(ying)響(xiang),在使(shi)用(yong)過程中需謹(jin)慎,要(yao)輕拿輕放,不能從(cong)高空掉(diao)落或者摔(shuai)碰。
8.3在測(ce)量完畢(bi)并退出(chu)測(ce)量狀態后(hou),關閉儀器(qi)電(dian)源,方可進行接線(xian)拆除。
8 .4如出現無法(fa)解決(jue)的問題,請及(ji)時與本公(gong)司取(qu)得(de)聯系。
十、售(shou)后服務
儀器自購買之日起一年內,屬(shu)產(chan)品質量問題免費包(bao)修(xiu)包(bao)換,終身(shen)提供維(wei)修(xiu)和技(ji)術服(fu)務。如發現儀器有異常情況或故(gu)障(zhang)請與公司及時聯系(xi),以便(bian)為(wei)您安排*便(bian)捷(jie)的(de)處(chu)理方案。